The 8700 Packetwave platform combines the advanced packet-networking capabilities of our Service-Aware Operating System (SAOS), which supports advanced OAM, QoS, and MPLS features and protocols, with the latest award-winning WaveLogic Photonics and WaveLogic 3 Nano technologies. My intuition tells me that it is most likely to be a configuration item in the Ciena 3916 that may be preventing communication with the Eero Box. Ciena’s 3903x Service Delivery Switch is an advanced Ethernet business demarcation device in a cost-effective and compact form factor. 2 questions : can I do it without stopping traffic, therefore without maintenance window and with trafic still on/alive ? or do I need absolutely to stop the chassis and all the trafic running through it ?@Street (Customer) Below are the steps to get console access of the device:. Hi @NNAJI O (Customer) Here's one point I found in the Waveserver User guide regarding maintenance:. The 3928 features a high-capacity 48 Gb/s switching fabric supporting four 1GbE or 10GbE ports and 8 100/100M/1000M ports in a compact 1RU chassis. Coupled with Ciena’s zero-touch provisioning, the 3903 optimizes first-in cost as well as TCO. port set port 9 description to-corsw-01-port-te1/1/9. @Paolo E (Customer) Thanks for reaching to ciena community. Any input or suggestion would be much appreciated!The section on port mirroring is in chapter 14 of the Advanced Ethernet Configuration Guide. The changes will be in effect only for a few minutes until I confirm those changes. interface create ip-interface VC VC1 ip X. The documentation leads me to believe that port 7 is the only port that can be used on the 3928 to enable benchmark tests, similar to how port 20 is the only port that can be used on the 5160. Number of Views 4. To consent to receive all cookies on all Ciena websites, click I acknowledge. 99> secret <yoursecret>" I've confirmed that RADIUS is configured via the. a. Rashmi Singh (Ciena Employee). cfm service enable service HNVL-TRIGGER-WEST. After examining Adv Enet Config guide for SAOS, I am confused regarding port VLAN,. pre-made ones from CienaI have configured a primary RADIUS server on our Z-series nodes following the procedure in the Z-series Engineering and Planning Guide. Ciena’s 3928 Service Delivery Switch is a cost-effective platform for 10 Gb/s Ethernet service delivery in a variety of business or mobile backhaul environments. We tried differend SFP's, cables and configuration, mostly changing back and forth between auto and 100/full. Does the 3928 v6 platforms support gRPC based telemetry streaming to a non MCP destination? Trying to assess the capabilities of the box to natively do this and stream off to our telegraf/influxDB engines. MCP presence of pre-5. 1. There are two interfaces in a active/active LACP configuration in each port-channel between the two. Ciena and the Ciena Logo are trademarks or registered. Click + Create. planning guide. To start provisioning sections of the Ciena via CLI, you will enter the command with various sub-commands. Then locate the product and SAOS version. 99. Service Delivery Switch. Universal Access Configuration (SAOS 6. 6500 - planning guide. Service Delivery Switch. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. Skip Content. This will effectively remove port 7 from the switch and you won't be able to use it for normal services. Provides advanced Carrier Ethernet and low TCO, powered by Ciena’s Service-Aware Operating System (SAOS) 3928. STEP 1 : Ask Field engineer to put IP: 172. MCP: How to restart a single container to clear its alert in Nagios. jstau (Ciena Employee) Brent, you need to get the installation manual from the customer and the 5400 installation configuration. To consent to receive all cookies on all Ciena websites, click I acknowledge. 21K how do I obtain proper console cable db-9 to rj-45 cable for the console. 19K how do I obtain proper console cable db-9 to rj-45 cable for the console. Number of Views 4. 2 but not other IP. To start provisioning sections of the Ciena via CLI, you will enter the command with various sub-commands. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. Ciena® cannot be responsible for unauthorized use of equipment and will not make allowance or credit for unauthorized use or access. To consent to receive all cookies on all Ciena websites, click I acknowledge. Nodal FCAPS) for 5400 NEs that have SONET/SDH cards and services configured on them. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the. We build the world’s most adaptive networks to address ever-increasing digital demands for richer, more connected experiences for all users. The 3924 is a carrier-grade. ciena 3932. For example, if you consider port 1,2,3 respectively as members of VLANs 100, 200 and 300, and you have uplink port 10 which you want to make member of every VLAN (similar to Cisco Trunk. Ciena® cannot be responsible for unauthorized use of equipment and will not make allowance or credit for unauthorized use or access. Sustainability Support Services. 323-4001-100 user guide had the references. The only other way I can think to do this is a little messy (static routes on ILANs pointing to/from the shelf). Supports 4 GbE NNI/UNI ports including 2 100/1000 Base-X SFP ports and 2 dual-mode ports: RJ-45 10/100/1000 Base-T and 100/1000 Base-X SFPs. 68K CLI command to look at the MAC address table on a particular VLAN. NEBS Level 3 configuration -40°F to +158°F (-40°C to +70°C) GR-63-CORE, Issue 4 – NEBS Level 3, Zone 4 RFC 5905 NTP Client. 220, subnet mask: 255. Has anyone ever seen an XC card constantly doing a "configuration search string" command on its own over and over? This is happening right now in my netowork. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. ERP 2. We have ciena 3928 and i couldn't console via putty after i gave all the relevant. 0 255. 233. Selected as Best Selected as Best Upvote Upvoted Remove Upvote. These attributes are available from System > Configuration. This question is closed. Ciena’s 3903x Service Delivery Switch is an advanced Ethernet business demarcation device in a cost-effective and compact form factor. Ciena® cannot be responsible for unauthorized use of equipment and will not make allowance or credit for unauthorized use or access. Ciena’s 3928 Platform is a cost-effective platform for 10 Gb/s Ethernet service delivery in a variety of business or mobile backhaul environments. By continuing, we assume that you consent to receive all cookies on all Ciena websites. 3903 Platform. Software Upgrade, License Activation and Nodal AT Ciena 3928. Number of Views 4. When a device. The 3928. 323-4001-100 user guide had the references. 14, with uniform security functionality between each of the hardware appliances. We build the world’s most adaptive networks to address ever-increasing digital demands for richer, more connected experiences for all users. Sole title to the Software and documentation, to any derivative works, and to any associated patents and copyrights, remains with Ciena or its licensors. Ciena’s 3930 Service Delivery Switch is an advanced packet networking system focused on the transition to high-bandwidth applications requiring sophisticated Quality of Service (QoS) capabilities, including mobile backhaul and Ethernet business services. The 3928 features a high-capacity 48 Gb/s switching fabric supporting four 1GbE or 10GbE ports and 8 100/100M/1000M ports in a compact 1RU chassis. I have also attached the CTP herewith for your reference. Ciena is a global leader in optical and routing systems, services, and automation software. In addition, issuing a "port xcvr show supported" lists those transceivers also as being supported by SAOS 6. CN3930_0061_5A> mstp disable. Regards, Fadil. I have a series of technical questions regarding the Ciena 39xx series (namely the 3903 and 3924) that I need to have answered. If you were given a /29, then get 6 IP addresses, Comcast takes 1 as the gateway, leaving you 5 usable. The 3928 features a. Sole title to the Software and documentation, to any derivative works, and to any associated patents and copyrights, remains with Ciena or its licensors. 220, subnet mask: 255. Check out the entries in the configuration guide for those two and see if they will suit your needs. Upcoming Events. ucol. L2VPN and Ethernet Services Configuration Guide for Cisco ASR 9000 Series Routers, IOS XR Release 7. 48K. I. By continuing, we assume that you consent to receive all cookies on all Ciena websites. By continuing, we assume that you consent to receive all cookies on all Ciena websites. 6500 Family. @Chelsi D2. 19K how do I obtain proper console cable db-9 to rj-45 cable for the console. Number of Views 4. 3. Tunnel creation via putty and. password : wwp. 16K how do I obtain proper console cable db-9 to rj-45 cable for the console. Skip Content. a. 2 6500 RA logs can result in 6500 management issues. pre-made ones from CienaCiena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. Seamlessly maximize your investment into the future by sustainably. +1 more. Seamlessly maximize your investment into the future by sustainably evolving your network with more scalability, flexibility. performance metrics available for end-customer SLA reporting. User :admin. The documentation leads me to believe that port 7 is the only port that can be used on the 3928 to enable benchmark tests, similar to how port 20 is the only port that can be used on the 5160. We would like to show you a description here but the site won’t allow us. ATA S H E E T 3928 Ciena’s 3928 Platform is a cost-efective solution for 10 Gb/s service delivery in a variety of business or mobile backhaul environments. 135. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. We have ciena 3928 and i couldn't console via putty after i gave all the relevant. nz on 2023-01-13 by guest the literature about language-in-education in such. On the Ciena Portal - Support / Documentation. LACP port/etherchannel traffic/load-balancing issues between ISP Ciena 3928 and Cisco ASR 1002-X. x Bias-Free Language The documentation set for this product strives to use bias-free language. Number of Views 4. 99. Number of Views 4. Enter the name in the Name field exactly as it appears in the 'Key and Name' column in the preceding table. System initialization changes ensure that control over the resets for all data plane devices is delegated to the SAOS application and early system initialization does not touch those reset lines. All the LEDs on the faceplate will be lit, then they will flash to indicate that the hard reset has been initiated. 365 of the U. Thanks! SuthaWe have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. pre-made ones from Ciena Stay informed and get Ciena's network insights emailed straight to your inbox. It say "waiting for the authentication server" and says incorrect password as shown below: login: su. Is it a low density or high density system? Which type of PDUs were ordered? What will be the full system build-out including quantity/types switch modules. 16K What is the default username and password for the 3903 box?We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. pre-made ones from CienaAlarms presented are "Equipment Configuration Mismatch" on all 3 fans as well as "Autoprovisioning Mismatch" on NTK539PB card slot. 19K How do I pull the serial number from devices using SNMP polling?Stacey P1 (Customer) asked a question. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. how it works ? i want to know about this cards ?I have NTK538BJ. 3801 XGS-PON Optical Network Unit. To consent to receive all cookies on all Ciena websites, click I acknowledge. On the Ciena Portal - Support / Documentation. pre-made ones from CienaHi Dana, NSI implies for "Network and Service Inventory" , as MCP is totally based on microservices based architecture and MCP uses a generic internal data model called the TPE/FRE Model, The TPE/FRE model allows MCP micro-services to promote re-use and be more generic and data-driven, the model supports multi-layer and device agnostic PCE,. pre-made ones from CienaMCP presence of pre-5. S. 6500 - planning guide. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. 18K I need to know the CLI command to show the running configuration / provisioning data of a 6500 device. This is a cheat list of the most used operational and troubleshooting Ciena Commands used in SAOS OS cli. you can choose the file. 00. Contacting Ciena For additional office locations and phone numbers, please visit the Ciena web site at Corporate Headquarters 410-694-5700 or 800-921-1144 Customer Technical. David G28 (Customer) asked a question. The documentation set for this product strives to use bias-free language. Any guidance is appreciated. 17K how do I obtain proper console cable db-9 to rj-45 cable for the console. 11 software and using the NTK667AA and NTK616BA. 6 Tb/s performance optics and 400G coherent pluggables to compact ROADMs and control plane automation, Ciena’s 6500 Family of Packet-Optical Platforms enables you to continually stay ahead of customer demands. 5. 16. To consent to receive all cookies on all Ciena websites, click I acknowledge. MCP provides a list of configurable parameters that are used for allocating SIDs. pre-made ones from CienaWe have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. Section 365 of the U. By continuing, we assume that you consent to receive all cookies on all Ciena websites. Contacting Ciena For additional office locations and phone numbers, please visit the Ciena web site at Corporate Headquarters 410-694-5700 or 800-921-1144 Customer Technical Support. I have static the required routes on DeviceA & B. cfm mep create service HNVL-TRIGGER-WEST port 24 type down mepid 1. After examining Adv Enet Config guide for SAOS, I am confused. Number of Views 4. Number of Views 4. 18K I need to know the CLI command to show the running configuration / provisioning data of a 6500 device. Upvote. The documentation leads me to believe that port 7 is the only port that can be used on the 3928 to enable benchmark tests, similar to how port 20 is the only port that can be used on the 5160. MCP5. 16K how do I obtain proper console cable db-9 to rj-45 cable for the console. Please refer the below snip from Page 1-422 of Configuration - Provisioning and Operating Guide 323-1851-310. S. Number of Views 1. It is also based on SAOS. Z-Series: Node unresponsive in Planet Operate due to throttling errors and High CPU utilization. x for Management access. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. The 3928 operates using the Ciena Service Aware Operating System (SAOS). you can use same for 5142. 74K. you can search when your in the chassis for possible commands. 255 longer-prefixes show ip route connected show. Now, we suddenly need to install these devices and configure a 100G service for one of our customers. Number of Views 4. The 3928 needs to reserve a port in order to have the hardware resources to run benchmark tests. 22K How do I pull the serial number from devices using SNMP polling?In Band Management (5160 <--> 3928) We have a 5160 that is located in our central office connected to our local management network. Hi @Muhammad Syahrul F (Customer) Below are the commands line to disable the STP. 18K how do I obtain proper console cable db-9 to rj-45 cable for the console. Number of Views 4. The first version of the autonegotiation specification was introduced in 1995 IEEE 802. snmp community t1 security-name public text-name public. 3928 Service Delivery Switch. Hi @Kiran J (Customer) , welcome to the Ciena Communities! Friday's can be a little quiet here, so I wanted to get back to you before the end of the day, but if you haven't already, you may want to refer to the 39XX/51XX Service Delivery, Aggregation and Virtualization Switches Command Reference guide (009-3265-010). 21K How do I pull the serial number from devices using SNMP polling?We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. It is also based on SAOS. 19K Customer Experience & Live Network Operations for Service Partners SAS161All of the BP installation guides state the the ilannet can be changed but keep the masks at /16/24. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. snmp vacm group public member public security-model v2c. Number of Views 4. Number of Views 4. Any help is appreciated. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. Expand PostDo you have any configuration in the 3932? We normally used 3903 for this purpose and had to put in a vlan cross connect configs to get traffic between ports. I am needing some guidance on setting up 2 traffic-profiles on port 1 for a DIA circuit with a CIR of 30/30Mbps. ping X. Does the 3928 v6 platforms support gRPC based telemetry streaming to a non MCP destination? Trying to assess the capabilities of the box to natively do this and. Copy private key to folder /etc/bp2/authkeys/reporting with. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. ciena 3905. From 1. The 3928 features a high-capacity 48 Gb/s switching fabric supporting four 10GbE/1GbE ports and 8 1GbE ports in a compact 1RU chassis. I have completed all the recommended actions According to the instructions: 323-4001-100_ (Waveserver_Guide) Page: Waveserver management and set up 4-23. cfm service set service HNVL-TRIGGER-WEST ccm-interval 100ms. With support of WaveLogicTM 5 Nano (WL5n), and both hard network slicing (FlexEthernet) and soft network slicing (Segment Routing), the 5166 is the ideal platform to simplify. Traffic-profiling can be done port based or vlan based. 19K how do I obtain proper console cable db-9 to rj-45 cable for the console. 255. Can I get a little clarification? Does the 3924 really have that level of grounding requirements? Expand Post. Solutions;. Building configuration. Features and benefits. I have a series of technical questions regarding the Ciena 39xx series (namely the 3903 and 3924) that I need to have answered. 01K views Log In to Answer Trending articles MCP: How to restart a single container to clear its alert in Nagios RLS: (Master) OTDR Traces, Settings, & Troubleshooting Ciena’s 3928 Platform is a cost-effective solution for 10 Gb/s service delivery in a variety of business or mobile backhaul environments. Cisco Nexus 5000 Series Switch CLI Software Configuration Guide Chapter31. Network Element should have ISIS (or any other IGP protocol) commissioned and SR Enabled. To consent to receive all cookies on all Ciena websites, click I acknowledge. The 5400 uses #6, #4, or #2 AWG depending on the system. I tried to use putty with serial port to login CIENA 3930 to load configuration, I can't talk to CIENA, it didn't sho… Number of Views 1. unless authorized by Ciena in writing; or. pre-made ones from CienaCiena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. Allows a field replaceable module for distributed VNF hosting on an. What I like to do is to take the OC-A certification exam without taking the 5 days led training. 3900 Family. If you have access to the Ciena Portal, then you should be able to access the configuration guides for any Ciena products which will have sample configurations. 3928> interface serial show with the Software unless it was supplied by Ciena in a form intended for reproduction; vii) Export or re-export the Software from the country in which it was received from Ciena or its authorized reseller. 3928 1; 5160 0; Ciena uses cookies to ensure that we give you the best experience when visiting. To consent to receive all cookies on all Ciena websites, click I acknowledge. Step 3: Configure SNMP Target and target parameters. planning guide. MCP & INOC, SDH & E1 Service configuration. 19. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. Low footprint 1RU in a nonblocking architecture with: - 6 x 1GbE/10GbE SFP+ ports - 2 x 100M/1GbE ports. Community Discussions. License Server: "Floating IP" onto a pair of LS in HA is not responding. Ciena Commands. I'm running 11. 3806 XGS-PON Weatherproof Optical Network Unit. RLS: (Master) OTDR Traces, Settings, & Troubleshooting. The 3928 needs to reserve a port in order to have the hardware resources to run benchmark tests. To start provisioning sections of the Ciena via CLI, you will enter the command with various sub-commands. If I replace that 5150 with a 5171 will I need a virtual switch with vlan 123 on. The 3928 has the following physical characteristics: • 2 dual-built in AC or DC power supplies —. port set port 9 acceptable. Number of Views 4. This is a cheat list of the most used operational and troubleshooting Ciena Commands used in SAOS OS cli. I'm absolutely new in Ciena (come from Juniper & Cisco). Routing and Switching. 03K how do I obtain proper console cable db-9 to rj-45 cable for the console. The 3948 addresses customers’ key needs, supporting routing, Multi-Protocol. 51K. Then locate the product and SAOS version. This enables one to perform service assurance and stats collection on those endpoints. boot-end-marker!!. step 1: Enable “global-cfm” and create maintenance domain in ValCLI on both ndoes, diag@CN5170_0006# cfm-global-config admin-state enable. Ciena reserves to itself and its licensors all rights in the Software andHi Chelsi, command-log show, I see is a very useful command, but this only lists what commands were last issued. mac show. 08K I need to know the CLI command to show the running configuration / provisioning data of a 6500 device. Does anyone know the console cable pinout for Ciena Waveserver ai (RJ45 to RJ45)? Is there an EIA number for this cable t…. Bias-Free Language. 0. Number of Views 4. To consent to receive all cookies on all Ciena websites, click I acknowledge. 8032 ring. Number of Views 4. We have ciena 3928 and i couldn't console via putty after i gave all the relevant. By continuing, we assume that you consent to receive all cookies on all Ciena websites. it will help you in understanding SAOS 10. By continuing, we assume that you consent to receive all cookies on all Ciena websites. No service management (no DVT or Prov’g for SONET/SDH switching) 6500. Where can I find user / configuration / troubleshooting manuals and release notes for the Ciena 3926 and 3928? I've been trying to find those on my. By continuing, we assume that you consent to receive all cookies on all Ciena websites. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. TXO has the CIENA 3928 in stock, along with a wide range of used and refurbished telecommunications equipment from all OEMs. 6. The compact, cost-effective open network edge platform is powered by a built-in. Waveserver*> interface serial-console show. To consent to receive all cookies on all Ciena websites, click I acknowledge. ciena 3911. pre-made ones from CienaCiena’s 3928 Platform is a cost-effective solution for 10 Gb/s service delivery in a variety of business or mobile backhaul environments. snmp target-params TestParamsV2c v2c security-name. pre-made ones from CienaWe have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. The version of soas is 6Note, the provisioning below will use the "#" as a remark / comment. 21K I need to know the CLI command to show the running configuration / provisioning data of a 6500 device. 99. 16. The 3930 incorporates a complete Operations, Administration, and Maintenance (OAM)[2] SAOS 6. Offers dual hot-swappable AC or DC power in a high-availability, temperature-hardened, 1RU package. To view the CONSOLE serial interface information. Search on 'serial'. virtual-switch Ethernet add vs VS1 ip-interface VC1 vlan 4070 port 1. pre-made ones from CienaThey provide a P2P IP block and a CA (customer assigned) IP block. Also for: 170-3930-900, 170-3930-910, 170-3930-930, 5160. MCP Hardware & Engineering Guide. By continuing, we assume that you consent to receive all cookies on all Ciena websites. 3928-A & 3928-B they are connected to each other on port 9 for both sides and I can run RFC test clean on EVC that have been built. Selected as Best Selected as Best Upvote Upvoted Remove Upvote. 73K. Hi, We have ciena 3928 and i couldn't console via. Ciena’s 3948 is a cost-effective router designed to address the requirements for higher capacity and end-to-end disaggregated IP services at the network access, supporting 4G. Download Data sheet 3926 Ciena’s 3926 Platform is a compact, smart CPE that delivers gigabit Ethernet service. Number of Views 4. 19K I need to know the CLI command to show the running configuration / provisioning data of a 6500 device. CLI command to look at the MAC address table on a particular VLAN. 5130. 22K how do I obtain proper console cable db-9 to rj-45 cable for the console. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. I can ping the mgmtbr0 IP from the Juniper but don't seem to be able to SSH to the. Number of Views 4. vlan add vlan 4700 port 1. Generate RSA public/private key pair through linux command ssh-keygen -t rsa. Enter the name in the Name field exactly as it appears in the 'Key and Name' column in the preceding table. 39K. I attached some commands to configure a VLAN in SAOS6 to 3920. 2 6500 RA logs can result in 6500 management issues. Web manuals and user guides for ciena 3930 series. I have the mgmtbr0 configured with an IP address and have that port directly connected to a Juniper ACX. Number of Views 4. This includes users and exploits. 14. As output I have not installed bot6th dynamic protocol. To consent to receive all cookies on all Ciena websites, click I acknowledge. To consent to receive all cookies on all Ciena websites, click I acknowledge. The 323-1955-802 Transceivers Reference RevAH lists XCVR-S80U49 and XCVR-S80U55 as compatible with practically all current Ciena systems, however, the 3928 does NOT have those listed as compatible transceivers. 009-3287-001 Standard Revision A Ciena Commands. We have ciena 3928 and i couldn't console via putty after i gave all the. 22K how do I obtain proper console cable db-9 to rj-45 cable for the console. 3928> configure <TAB> show save. x software stream, the 3926 provides a wide range of service offerings, including TDM, MEFWe have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. This is a cheat list of the most used operational and troubleshooting Ciena Commands used in SAOS OS cli. By continuing, we assume that you consent to receive all cookies on all Ciena websites. The unit is View and Download Ciena 3930 Series hardware installation and start-up manual online. 3928> user lockout-policy show. Upvote Upvoted Remove Upvote. Can't find a good configuration guide on the Ciena side to actually enable this via CLI on the 3928, Any help/links/anything would be. Solutions;. We have ciena 3928 and i couldn't console via putty after i gave all the relevant configuration on the serial port. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination. Nodal FCAPS) for 5400 NEs that have SONET/SDH cards and services configured on them. PM stats can be enabled on flow-points & IP interfaces on the device. pre-made ones from CienaSatoko Kobayashi (Ciena Employee) asked a question. 0.